A LiFePO4 pack is a row of cells in series, and the pack is only as good as the cell that hits a limit first. Cell delta, the highest cell voltage minus the lowest, is the quickest way to see whether the cells are keeping together. It is also easy to misread.
Paste your own cell voltages into the free cell imbalance checker to follow along; it shows the delta, the high and low cell and what the spread means at that point of the charge.
Why the delta changes with the charge
LiFePO4 has a flat voltage curve. Between about 3.20 V and 3.35 V per cell, a resting cell holds most of its charge, roughly 20 % to 90 % in the published charts. In that range, two cells holding quite different amounts of charge can read only a few millivolts apart.
Near full and near empty, the curve turns steep. The same difference in charge now shows as tens of millivolts. That is why a pack can show a delta of a few millivolts at mid-charge and several times as much at the top of the same charge, without anything having changed.
So the first rule is to compare like with like: read the delta at the same point every time. The top of a charge, when the cells are near 3.4 V and the BMS is balancing, is the most revealing.
What the BMS does about it
Most smart BMS boards, JBD and Daly included, balance passively. When cells sit above a start voltage and differ by more than a set threshold, the BMS bleeds a small current from the highest cells through resistors so the others can catch up. It only works while the pack spends time near full, which is why packs that are never fully charged can drift.
An active balancer moves charge from high cells to low ones instead of turning it into heat, and can work faster. Neither kind restores a cell that has lost capacity; balancing tidies small differences.
The start voltage, the threshold and whether balancing runs only while charging are settings in your BMS maker’s app.
When a delta is worth attention
- It keeps growing. The same cell drifts further over weeks, even after full charges.
- It is always the same cell. A cell that is always first to the top, or first to the bottom, has less usable capacity or more resistance than its neighbours.
- The BMS trips early. Charging stops on cell over-voltage before the pack reaches its expected charge, or discharge stops on cell under-voltage while others still hold plenty.
- It shows under load. A cell that sags more than the others when current flows may have higher internal resistance.
A single high reading during charging is not one of these. A trend is.
Watching the trend
A trend needs history. Amphour reads every cell from JBD and Xiaoxiang BMS boards (tested on real hardware) and Daly boards (experimental) over Bluetooth on iPhone and iPad, logs them every second while connected, and keeps that history on the device. It alerts when the delta passes 50 mV by default, a conservative starting point you can change with Amphour Pro, and its PDF battery health report charts cell delta over 30 days, 90 days or a year, which is useful for a warranty claim or when selling a used battery.
It reads only: balancing and protection settings stay with the BMS and its maker’s app.
If a cell keeps drifting, talk to your battery maker before opening the pack. Opening a battery, rebalancing cells by hand and changing protection settings is work for someone qualified.

